  • Multi-layer design for 6 bar inflation pressure.
  • Maximum 3 bar back/test pressure.
  • Pipe diameters from 100mm to 800mm.
  • Maximum inflation and back/test pressure must not be exceeded.

Vetter High Pressure Pipe Stoppers 340 Vetter High Pressure Pipe Stoppers

Technical Specifications

Range
Max Inflation 
Pressure
(bar)
Pipe
Diameter
(mm)
Diameter
Approx
Cylinder
Length
(mm)
Total
Length
(mm) 
Air
Requirement
Approx
(litres) 
Weight
(kg) 
Max
Back 
Pressure
(bar) 
Inside 
Pipeline
Outside
Pipeline 
100 / 200 6 0.5 100 – 200 90 510 555 105 1.5 3
200 / 300 6 0.5 200 – 300 195 650 695 338 3.1 3
300 / 400 6 0.5 300 – 400 295 735 780 527 7.0 3
500 / 600 6 0.5 400 – 500 450 1110 1155 1550 20.0 3
800 6 0.5 800  785 1810 1855 6160 44.0 3

How can MGF Support your project?

Call now and speak to one of our team

01942 402 700

Register for Updates

Register your email address now to receive updates on all MGF products.

(MGF GRiPSHORE™) is a simple but widely applicable solution that will radically improve health and safety in shallower trench excavations. It will potentially instigate a culture change, especially with SME’s and utility operatives. Effective use of lightweight materials and basic analysis of soil mechanics provides a quick to install and versatile sustainable low cost solution that reduces CO2 emissions and negates the need for plant

- Award Panel, BCIA Awards 2015

Accreditations

The cookie settings on this website are set to "allow cookies" to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click "Accept" below then you are consenting to this.

Close